LCOE Explained: What Levelized Cost of Energy Means and How to Calculate It

EcoFlow

LCOE, short for levelized cost of energy (or electricity), is the number analysts use to compare the lifetime cost of different power sources. It spreads the full cost of building and running a generator over all the electricity it's expected to make. That makes comparisons easier, but it leaves some things out, and it doesn't measure batteries well. This guide explains what LCOE means using EIA's definition, walks through the formula in plain words, covers why storage uses a separate measure called LCOS, and shows how the idea applies to a small solar and battery setup.

What Is LCOE?

LCOE is the average cost of each unit of electricity over a generator's whole life. It rolls building, running, and financing the plant into one number. That lets you compare a solar farm, which costs a lot up front but burns no fuel, with a gas plant that needs fuel every day.

How EIA Defines LCOE

So what is LCOE in official terms? The U.S. Energy Information Administration (EIA) calls it "the estimate of the revenue required to build and operate a generator" over a set cost recovery period. Put simply, LCOE means the price each megawatt-hour must fetch for the plant to cover its costs, including a return for investors. Some reports call it the levelized electricity cost.

The word "levelized" is the key. Instead of showing a high cost in the first year and a low cost later, the math flattens everything into one steady cost per unit across the plant's life. That's what lets you line up a solar project and a gas project side by side.

LCOE, LCOS, and LACE at a Glance

The LCOE meaning gets clearer next to its two sister measures. In EIA's levelized cost estimates, the agency publishes all three side by side.

Measure

What it estimates

Where it fits

LCOE (levelized cost of electricity)

Revenue needed per unit of electricity to build and run a generator

Power plants such as solar, wind, gas, and nuclear

LCOS (levelized cost of storage)

Revenue needed per unit of electricity a storage system sends back out

Batteries and other storage

LACE (levelized avoided cost of electricity)

Revenue available to that plant over the same period

A rough measure of value to the grid

EIA adds that real build decisions are more complex than simply setting value against cost. A simpler cousin of LCOE is the solar payback period, which asks how many years it takes for savings to cover what you paid. Payback tells a homeowner when the money comes back, while LCOE tells you what each unit of energy really costs.

For a small solar and battery setup, the same thinking applies. The difference is that generation and storage have to be counted separately.

Applying LCOE Thinking to a Small Solar and Battery Setup

Panels make electricity, but a battery only stores it. So the cost of solar energy and the cost of storing that energy are two separate numbers. A power station's rated watt-hours show what it holds on one charge, not what it delivers over its life.

Solar charges it; storage costs moreSolar charges it; storage costs more

Generation Cost vs. Storage Cost

Start with the panels. Their cost, plus mounts and cables, gets spread over the kilowatt-hours they produce in their working life, much like a small-scale LCOE.

The battery side is different. Its cost gets spread over the energy it actually delivers, which depends on these factors:

  • Real cycles: how often you charge and drain it, not the rated count.

  • Losses: some energy is lost going in and coming out.

  • Fading capacity: a battery holds a little less as it ages.

  • Replacement: any part that wears out early adds to the total.

Losses show up even on the grid. EIA found that utility-scale batteries returned about 82% of the electricity put into them on average in 2019. Adding a battery doesn't make solar energy cheaper; it shifts that energy to later in the day, and the shift has its own cost.

Choosing Storage for a Small Solar Setup

If you power a small workspace or cabin with panels and a battery, two cost questions follow. What does the solar energy cost, and what does storing it cost? EcoFlow DELTA Gen4 power stations store solar energy, while the panels make it. Count both sides, including losses and cycle life, before you compare.

Say your workspace runs lights and a laptop. A 3kWh unit can store a day of solar production from compatible panels, which is the job the EcoFlow DELTA 3000 Gen4 is built around.

EcoFlow DELTA 3000 Gen4
• Longest Runtime¹: Powers a refrigerator for up to 58 hours — 17 hours (41.5%) longer than the industry average for 3kWh portable power stations. • Powers Most Home Appliances: Delivers 3,600W of continuous output and 7,200W of surge power⁴. • Compact Yet Powerful: The smallest and lightest⁵ portable power station in its class with 3kWh capacity and 3,600W output. •UPS Backup with <10 ms Transfer Time: Switches to backup power within 10 ms when an outage occurs. • Up to 5-Year Warranty: Includes 3-year standard warranty and 2-year extended warranty available upon EcoFlow App registration.

A fridge running all day, or long gaps between sunny days, calls for more storage. The EcoFlow DELTA 3800 Gen4 holds 3.7kWh, takes solar through two inputs, and can grow with extra batteries.

EcoFlow DELTA 3800 Gen4
•Longest Runtime: Powers a refrigerator for up to 70 hours — 17 hours (32.6%) longer than the industry average for 3-4kWh portable power stations. •Powers Most Home Appliances: Delivers 3,600W of continuous output and 7,200W of surge power⁴ . •Compact Yet Powerful: The smallest and lightest⁵ portable power station in its class with 3-4kWh capacity and 3,600W output. •4–12 kWh Expandable Capacity: Compatible with EcoFlow DELTA Pro 3 Smart Extra Battery and EcoFlow DELTA 3 Max Plus (2,048 Wh) Smart Extra Battery. • UPS Backup with <10 ms Transfer Time: Switches to backup power within 10 ms when an outage occurs.

Neither unit makes power on its own. Neither is cheaper per kWh just because it holds more, and here's how the two divide the job:

  • EcoFlow DELTA 3000 Gen4: a solar storage budget for small workspace loads.

  • EcoFlow DELTA 3800 Gen4: fridges and longer runtime, with room to expand.

EcoFlow's US pages list both as preorder items, with the EcoFlow DELTA 3800 Gen4 shipping in late November and the EcoFlow DELTA 3000 Gen4 in early December, so confirm delivery timing for your address. Don't count on either for an outage that's already happening.

A Simple Storage Cost Example

The numbers below are examples, not measurements. Swap in your own daily use and prices.

Example input

Value

Energy delivered per day from storage (example)

1.5 kWh

Days used per year (example)

200

Energy delivered per year

300 kWh

Generation cost per kWh produced (panels)

(panels + mounts + cables) ÷ (kWh the panels produce over their life)

Generation cost per kWh delivered from storage

Generation cost per kWh produced ÷ round-trip efficiency

Storage cost per delivered kWh

(power station + storage-related accessories + any replacements) ÷ (kWh delivered to your devices over its expected life)

Total cost per kWh delivered from storage

Generation cost per kWh delivered + storage cost per delivered kWh

Don’t add panel cost and storage cost as they stand. Panel cost is counted per kWh the panels produce, while storage cost is counted per kWh that reaches your devices, and some energy is lost on the way through the battery. So divide the panel cost by the round-trip efficiency first. Say panel energy costs $0.10 per kWh and round-trip efficiency is 80% (example figures only). You need 1.25 kWh of solar for every 1 kWh delivered, so the generation cost becomes $0.125 per delivered kWh. Then add the storage cost per delivered kWh.

Use your own measured efficiency where you can. EcoFlow rates both Gen4 batteries to keep 70% of their starting capacity after 6,000 cycles, but your delivered energy depends on how often you use the unit. Storage math also depends on how long LiFePO4 batteries last.

Here’s how to fill in the storage row. First, total what you paid for the power station and any storage accessories. Next, multiply the energy it delivers to your devices each year by the years you plan to use it, then trim that figure for fading capacity. Divide the first number by the second, and you have your storage cost per delivered kWh.

Every cost in the table is now counted per kWh that reaches your devices. Battery losses are applied only in the round-trip efficiency step, so they aren’t counted twice.

The LCOE Formula in Plain Words

The LCOE formula divides the present value of all costs by the present value of all energy produced. Discounting accounts for the time value of money, since a dollar spent 10 years from now counts for less than a dollar today. A higher capacity factor spreads the same costs over more energy, which lowers LCOE.

Why Discounting Matters

Written out, the levelized cost of energy formula looks like this. Each year's costs and output get shrunk by the discount rate before they're added up.

LCOE = (sum of discounted capital, operating, fuel, and financing costs over the plant's life) ÷ (sum of discounted electricity produced over its life)

Discounting matters most when most of the money goes out on day one. Solar and wind fit that pattern, since nearly all their cost is the build. A gas plant spends more of its money on fuel in later years, so the timing of its costs looks very different.

A Simple Worked Example

Numbers make the formula easier to follow. The plant below is made up for illustration, and none of these figures come from EIA.

Example input (illustration only)

Value

Build cost, paid in year zero

$100,000

Upkeep each year

$2,000

Electricity produced each year

150 MWh

Life of the plant

20 years

Discount rate

5%

LCOE without discounting

$140,000 ÷ 3,000 MWh, about $46.67 per MWh

LCOE with 5% discounting

about $66.83 per MWh

Why does the discounted number come out higher? The build cost is paid today at full value, while the energy arrives over 20 years and each later megawatt-hour counts for less. A higher discount rate would push the result up even more, and a longer life or more output each year would pull it down.

The Inputs That Move the Number

EIA's levelized cost methodology lists capital costs, operations and maintenance, fuel, financing, and an assumed utilization rate as its key inputs. It also uses a 30-year cost recovery period. Here's what each input does:

  • Upfront cost: building or buying the equipment.

  • Operations and maintenance: yearly upkeep, fixed and variable.

  • Fuel: zero for solar and wind, a big share for gas plants.

  • Discount rate: a higher rate raises LCOE for projects with high upfront costs.

  • Lifetime: more years of output spread the upfront cost thinner.

  • Capacity factor: how much of its possible output a plant actually produces.

  • Degradation: equipment that makes less each year shrinks the energy side.

Here is how EIA defines capacity factor: actual output compared with the most a generator could have produced over the same period. Capacity factor alone doesn't tell you how much energy a plant makes, since a 1 MW plant at 50% produces as much each year as a 2 MW plant at 25%. So compare plants with the same rated capacity, life, yearly costs, discount rate, and time period. Under those conditions, a plant at 50% produces twice the energy of one at 25%, so its LCOE is about half.

Where EIA's Numbers Come From

EIA publishes its LCOE, LCOS, and LACE estimates with each Annual Energy Outlook. EIA's AEO2026 levelized cost report, released April 8, 2026, covers new resources entering service in 2031. Those figures describe new power plants entering service in a future year, so they won't match the cost of a home solar setup. If you quote them, include the dollar year and units. On the energy side, everything starts when you calculate solar panel output for your own roof or yard.

Even a careful formula has blind spots. That's where LCOE's limits come in.

Limits of LCOE

LCOE is a starting point, not the full answer. It doesn't care when power is produced or what that power is worth to the grid at that hour. That's why EIA pairs it with other measures.

Energy value shifts by the hourEnergy value shifts by the hour

What LCOE Leaves Out

EIA notes that policy, technology, and geographic factors are hard to fold into a single metric. Its AEO2026 report also warns that direct LCOE or LCOS comparisons across technologies can mislead. A solar farm that peaks at noon and a gas plant that can run at 6 p.m. may cost about the same per megawatt-hour, but they don't fill the same need. Here's what LCOE leaves out:

  • Timing: evening power is often worth more than midday power.

  • Reliability: plants you can run on demand cover gaps that weather-dependent sources can't.

  • Grid costs: new power lines and backup capacity sit outside a single plant's LCOE.

  • Policy: tax credits change the math, and EIA's stated values include them for eligible technologies.

LCOE vs. Your Electricity Bill

LCOE also isn't your utility bill, which adds delivery and other charges on top of generation. Compare LCOE with your electricity cost per kWh to see how far apart the two numbers can be. Utility rates also shift with your plan, the season, and sometimes the time of day. So a low LCOE for one type of plant doesn't mean your own bill will drop by the same amount.

Conclusion

LCOE is EIA's estimate of the revenue a generator needs to build and operate over its cost recovery period, and storage gets its own measure, LCOS. Use LCOE to compare generators, then add timing and reliability before you draw conclusions. In your own planning, keep generation and storage costs apart. For small solar storage, the EcoFlow DELTA 3000 Gen4 or EcoFlow DELTA 3800 Gen4 can store energy from separate panels, so check delivery timing for your address first.

FAQs

What does LCOE mean?

LCOE stands for levelized cost of electricity, also called the levelized cost of energy. EIA describes it as the estimated revenue a generator needs to cover building and operating it over its cost recovery period. It's usually shown as a cost per megawatt-hour, so different power sources can be compared on the same scale.

What is the LCOE formula?

Add up all the discounted costs over a plant's life, including construction, upkeep, fuel, and financing. Then divide by all the discounted electricity it produces. Discounting makes money and energy in later years count for less than they do today.

What is LCOS?

LCOS is the levelized cost of storage, which applies the same lifetime cost idea to batteries per unit of electricity sent back out. EIA estimates it separately and counts the cost of charging power instead of fuel.

Why isn't LCOE enough to compare power sources?

It shows cost, not value, and ignores when power is produced and how reliable a source is. EIA pairs it with LACE and LCOS for a fuller picture. Grid costs and policy, such as tax credits, can also shift which option makes sense.

Does a battery have an LCOE?

No. A battery stores power made somewhere else, so it's measured with LCOS. Its rated watt-hours should never stand in for lifetime energy. Count the energy it actually delivers over its life, after losses.

For press requests or interview opportunities, reach out to our media team

media.na@ecoflow.com
Solar Energy