Like any gas generator, it must be placed outside 15 feet from doors and windows to prevent carbon monoxide poisoning. The Smart Generator automatically shuts off if it detects dangerous carbon-monoxide levels, but isn't a substitute for having CO detectors in other parts of your house.
Go to More and then Maintenance to find more details or check out the user manual shipped with the Smart Generator.
Unleaded gasoline.
1. Turn the maintenance cover knob to OPEN and take off the maintenance cover. 2. Take off the spark plug cap. 3. Use the spark plug socket and turn it counterclockwise to remove the spark plug. 4. Check for any color fading and remove any carbon deposits. The porcelain center around the spark plug center electrode should be moderately light brown if it is in good condition. 5. Check the model of the spark plug and that it has sufficient clearance.
1. Unscrew the bolts. 2. Take off the muffler cap, muffler block, and spark plug arrestor. 3. Clean the carbon deposits on the muffler block and the spark plug arrestor gently with a wire brush to avoid damaging or scratching the muffler block and spark plug collector. 4. Check whether the muffler block or the spark plug arrestor is damaged, and replace it if damaged. 5. Reinstall the parts in order.