Welcome to EcoFlow Support

Welcome to EcoFlow Support

We're here for you

FAQ

Battery heating

Manual discharge heating function: Manually discharge and heat the battery via the Console or app when the battery temperature <0°C and SOC>50%. When the battery SOC ≤ 30% or the battery temperature is higher than 10°C, the battery discharge heating is automatically switched off. Automatic recharge heating function: Automatic heating on recharge In order to extend the battery life and maintain optimal performance, it will continuously heat the battery up to the optimal operating temperature automatically (BP2000 — 18°C, BP5000 — 23°C) when there is sufficient input power (>250W is needed to heat a battery). The battery charge heating is automatically switched off when power is insufficient for heating so as to prioritize recharging.

What is the maximum DC output of the Power Hub battery port?

40–57.6V⎓55A

What is Power Hub's maximum bypass current?

50A

What is Power Hub's maximum recharging power?

ALT1 & PV1: 4000W ALT2/3 & PV2/3: 1600W AC: 4000W The maximum recharging power for the device as a whole is 11kW

Once Power Hub is in low-light mode, can you manually exit low-light protection mode and reactivate PV input?

If there is no PV input after illumination conditions change (example: nightfall), then low-light protection is enabled. Manually exiting low-light protection Method 1: Turn PV input off and on again. Method 2: Remove the PV input cable and wait at least 10 seconds before reconnecting it.

Contact us