Manual discharge heating function: Manually discharge and heat the battery via the Console or app when the battery temperature <0°C and SOC>50%. When the battery SOC ≤ 30% or the battery temperature is higher than 10°C, the battery discharge heating is automatically switched off. Automatic recharge heating function: Automatic heating on recharge In order to extend the battery life and maintain optimal performance, it will continuously heat the battery up to the optimal operating temperature automatically (BP2000 — 18°C, BP5000 — 23°C) when there is sufficient input power (>250W is needed to heat a battery). The battery charge heating is automatically switched off when power is insufficient for heating so as to prioritize recharging.
40–57.6V⎓55A
50A
ALT1 & PV1: 4000W ALT2/3 & PV2/3: 1600W AC: 4000W The maximum recharging power for the device as a whole is 11kW
If there is no PV input after illumination conditions change (example: nightfall), then low-light protection is enabled. Manually exiting low-light protection Method 1: Turn PV input off and on again. Method 2: Remove the PV input cable and wait at least 10 seconds before reconnecting it.