Welcome to EcoFlow Support
We're here for you
Recommended Search

We're here for you
Recommended Search
Charging priority: low voltage photovoltaic > high voltage photovoltaic > 5 + 8 interfaces (including Smart Home Panel 2) > mains
Yes, but the transfer switch should be connected to the power station's AC output port. You should disconnect the circuits from the grid before the power station supports them. The total power consumption of the circuits should not exceed the output power rating. The output will not be grounded if the power station is not connected to the grid.
Unfortunately, EcoFlow DELTA Pro Ultra cannot connect and feedback to the grid.
A 274 fault is caused by a C20 outlet overcurrent. After a C20 overcurrent, it will switch to INV and discharge normally, as long as you have a split load. At this time, the maximum power should be 7200W. The custom charging mode does not support X-Boost. Once the output load exceeds the set charging power, it will cause the 274 fault. If the user needs to charge and discharge a dryer simultaneously, the C20 must be set to fast charging mode.
EcoFlow Smart Generator can charge EcoFlow DELTA Pro Ultra using an EcoFlow AC Charging Cable (NEMA 5-15P to C19). EcoFlow DELTA Pro Ultra can not be charged using DC through an XT150 cable. Third-party generators can charge EcoFlow DELTA Pro Ultra using the EcoFlow AC Generator Charging Adapter. The EcoFlow Smart Generator can be auto-switched on or off through the EcoFlow app.