Priority of the three recharging modes (PV, ALT and AC)

PV>AC>ALT>Smart Generator. Lower priority sources for recharging automatically stop working when the recharging power exceeds what the battery needs to recharge.

Battery heating

Manual discharge heating function: Manually discharge and heat the battery via the Console or app when the battery temperature <0°C and SOC>50%. When the battery SOC ≤ 30% or the battery temperature is higher than 10°C, the battery discharge heating is automatically switched off. Automatic recharge heating function: Automatic heating on recharge In order to extend the battery life and maintain optimal performance, it will continuously heat the battery up to the optimal operating temperature automatically (BP2000 — 18°C, BP5000 — 23°C) when there is sufficient input power (>250W is needed to heat a battery). The battery charge heating is automatically switched off when power is insufficient for heating so as to prioritize recharging.

What is the maximum DC output of the Power Hub battery port?

40–57.6V⎓55A

What is Power Hub's maximum bypass current?

50A

What is Power Hub's maximum recharging power?

ALT1 & PV1: 4000W ALT2/3 & PV2/3: 1600W AC: 4000W The maximum recharging power for the device as a whole is 11kW